MODEL
|
LCM-40
|
OUTPUT
|
SELECTABLE
CURRENT Note.3
|
350mA
|
500mA
|
600mA
|
700mA
|
900mA
|
1050mA
|
DC
VOLTAGE
|
2
~ 100V
|
2
~ 80V
|
2
~ 67V
|
2
~ 57V
|
2
~ 45V
|
2
~ 40V
|
RATED
POWER
|
42W
|
RIPPLE
CURRENT
|
plus/minus
5%
|
RIPPLE
& NOISE (max.) Note.2
|
700mVp-p
|
NO
LOAD OUTPUT VOLTAGE (max.)
|
110V
|
65V
|
CURRENT
ACCURACY
|
plus/minus
5%
|
SETUP,
RISE TIME Note.5
|
1000ms,
80ms / 230VAC at rated power
|
HOLD
UP TIME (Typ.)
|
16ms/230VAC
at rated power
|
INPUT
|
VOLTAGE
RANGE Note.4
|
180
~ 295VAC 254 ~ 417VDC
|
FREQUENCY
RANGE
|
47~63Hz
|
POWER
FACTOR
|
PF≥0.975/230VAC,
PF≥0.96/277VAC at rated power (Please refer to "Power Factor Characteristic"
section)
|
TOTAL
HARMONIC DISTORTION
|
Total
harmonic distortion will be lower than 20% when output loading is 75% or higher
|
EFFICIENCY
(Typ.)
|
91%
|
AC
CURRENT
|
0.23A/230VAC
0.2A/277VAC
|
INRUSH
CURRENT (Typ.)
|
COLD
START 20A (twidth=260us measured at 50% Ipeak) at 230VAC
|
LEAKAGE
CURRENT
|
<0.5mA / 240VAC
|
PROTECTION
|
SHORT
CIRCUIT
|
Constant
current limiting, recovers automatically after fault condition is
removed
|
OVER
VOLTAGE
|
110
~ 130V
|
Protection
type : Shutdown o/p voltage, re-power on to recover
|
OVER
TEMPERATURE
|
90 degrees
Celsius plus/minus10 celsius degree(RTH2)
|
Protection
type : Shut down o/p voltage, re-power on to recover
|
FUNCTION
|
AUXILIARY
POWER
|
12V
@ 50mA for driving fan; Tolerance plus/minus 5%
|
TEMP.
COMPENSATION
|
By
external NTC(not provide with the power supply), please see "Temperature
compensation operation"
|
DIMMING
|
Please
refer to "Dimming Operation" section
|
SYNCHRONIZATION
|
Please
refer to "Synchronization Operation" section
|
ENVIRONMENT
|
WORKING
TEMP.
|
-30
~ +60degrees
Celsius (Refer to "Derating Curve")
|
WORKING
HUMIDITY
|
20
~ 95% RH non-condensing
|
STORAGE
TEMP., HUMIDITY
|
-40
~ +80degree Celsius,10~95% RH
|
TEMP.
COEFFICIENT
|
plus/minus
0.03 % /degrees
Celsius (0 ~ 50degrees
Celsius)
|
VIBRATION
|
10
~ 500Hz, 5G 12min./1cycle, period for 60min.each along X, Y,Z
axes
|
SAFETY
& EMC
|
SAFETY
STANDARDS
|
UL8750,
ENEC EN61347-1, EN61347-2-13,EN62384 independent approved
|
DALI
STANDARDS
|
Comply
with IEC62386-101, 102, 207
|
WITHSTAND
VOLTAGE
|
I/P-O/P:3.75KVAC
|
ISOLATION
RESISTANCE
|
I/P-O/P:>100M
Ohms / 500VDC / 25degrees
Celsius / 70% RH
|
EMC
EMISSION
|
Compliance
to EN55015, EN61000-3-2 Class C(≥40% rated power) ; EN61000-3-3
|
EMC
IMMUNITY
|
Compliance
to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV),
criteria A
|
OTHERS
|
MTBF
|
193.6K
hrs min. MIL-HDBK-217F (25degrees
Celsius)
|
DIMENSION
|
123.5*81.5*23mm
(L*W*H)
|
PACKING
|
0.24Kg
; 54pcs/15Kg/1.12CUFT
|
NOTE
|
1.
All parameters NOT specially mentioned are measured at 230VAC input, rated load
and 25celsius degree of ambient temperature.
2.
Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.
Please refer to "DIP Switch Table" section.
4.
Derating may be needed under low input voltages. Please check the static
characteristics for more details.
5.
Length of set up time is measured at cold first start. Turning ON/OFF the power
supply may lead to increase of the set up time.
6.
Efficiency is measured at 500mA/80V output set by DIP switch.
7.
No load power consumption<1.2W is measured at 180 277VAC, with lighting fixture connected and output current dimmed to 0%.
8.
The power supply is considered as a component that will be operated in
combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC
Directive on the complete installation
again.
|